| [1] Influence of winding and positioning defects on current
measurement with a Rogowski coil IEEE Transactions on Magnetics, A paraître, URL, Abstract HUSSON Esteban, GUYOMARCH Frédéric, LE MENACH Yvonnick, JOYEUX Patrice, PUPIER Alexandre |
The Rogowski coil is a well-known transducer device use for its linear or large bandwidth characteristic, but it’s quite
a challenge to wind a perfect Rogowski coil to minimize the current measurement error. In this paper, we will discuss the
influence of different winding and positioning defects such as coil and turn tilt, turn density, and conductor positioning
on current measurement. Using Sobol’s method combined with Monte Carlo method, this study aims to highlight the
manufacturing defects that have the worst influence on the actual current measurement accuracy. |